Spektrometry Hyperfine
Systemy skonfigurowane i "szyte na miarę"
HyperFine HF Series Spectrometers
Stunning ~1 pm Resolution or Incredible 30 pm Resolution over the Entire Visible
HyperFine HN Series Spectrometers
Compact Spectrometers for Bright Sources with ~25pm Resolution
Brillouin HyperFine Spectrometer
The Ultimate Brillouin Spectroscopy Tool
UltraBright Spectrometers
100X the light. No Slit. Boom. Spectrum. Done
Ultra OSA
Picometer resolution across the entire band in milliseconds
Custom Spectrometers
You won't find these in an optics catalog... The cool pictures are worth checking out.
Masz pytania?
Napisz do nas
HyperFine HF Series for Weak Sources
Kompaktowe spektrometry o rozdzielczości pikometrów do słabego lub rozproszonego światła.
The HyperFine series of spectrometers for low intensity sources are designed for measuring hyperfine spectra and subtle spectral shifts from scattered light or distributed sources. The HyperFine spectrometer from LightMachinery is a compact spectrometer capable of 1 picometer resolution. Enabled by VIPA etalons produced by LightMachinery's patented fluid jet polishing technology.
The HyperFine HF Series spectrometers are ideal for measuring fine features in plasmas, pulsed laser characterization and for measuring the small spectral shifts from Brillouin or Raman scattering. Simple PC based software allows the user to review spectra in real time and save or export for more analysis. LabView drivers enable the HyperFine spectrometer to be integrated into automated experimental setups.
Check out the latest research papers that have been published by researchers using the HyperFine spectrometers here.
Features
- FAST, No moving parts (single shot laser spectrum analysis)
- Sub picometer resolution
- Fiber optic input
- Quick data acquisition and export
- Simple USB interface
- LabView Drivers
Benefits
- Fast
- Compact
- Can resolve hyper fine spectra below 1 picometer
- Ultra-reliable
- LightMachinery's legendary customer support
Light sources characterization
- Lasers of all types
- Single shot pulsed laser spectrum
- Super luminescent diodes
- Gas discharge lamps, etc
Spectroscopy
- Plasma spectroscopy
- High-precision gas spectroscopy
- Brillouin or Raman spectroscopy
- Femtosecond comb fingerprinting spectroscopy
- Spectral-domain optical coherence tomography, etc
- Solar spectroscopy
- Astronomical spectroscopy
- Ultra low frequency Raman
- Undergraduate physics and chemistry laboratories
- Zeeman splitting
- Hyperfine magnetic structure of elements
- Hydrogen structure
- Doppler shift of Fraunhofer lines due to sun rotation
Passive components characterization
- Notch filters
- Etalons
- Fiber Bragg gratings, etc
Software
Technical specification
Part Number | Spectral Region | Form Factor | Total range | Simultaneous range | Resolution* | Resolution |
with manual grating rotation | pm | 1/cm | ||||
HF-8888-UV | UV | C | 200 - 400nm | Fixed 60nm range | <30pm | 0.9/cm |
HF-8888-UVLIBS | UV (Gated) | C | 200 - 400nm | Fixed 60nm range | <30pm | 0.9/cm |
HF-9332 | VIS | C | 450 - 700nm | Fixed 250nm range | <30pm | 0.9/cm |
HF-9353 | NIR | C | 750 -1050nm | Fixed 300nm range | <40pm | 0.5/cm |
HF-7888 | UV Vis NIR | E | 350 -1080/0nm | Fixed 3nm - 8nm range | 0.3pm - 0.8pm | 0.02/cm |
HF-8989-1 | VIS | A | 425 - 500 nm | 17 nm | 1.7 pm | 0.08/cm |
HF-8989-2 | VIS | A | 500 - 600 nm | 16 nm | 1.6 pm | 0.05/cm |
HF-8989-2e | VIS | A | 525 - 640 nm | 16 nm | 1.6 pm | 0.05/cm |
HF-8989-3 | VIS | A | 600 - 700 nm | 16 nm | 1.6 pm | 0.04/cm |
HF-8995-1 | NIR | A | 700 - 800 nm | 20 nm | 2.0 pm | 0.03/cm |
HF-8991-3 | NIR | A | 800-950 nm | 25 nm | 2.0 pm | 0.02/cm |
HF-8995-2 | NIR | A | 950 - 1100 nm | 25 nm | 2.5 pm | 0.02/cm |
HF-8995-3-PLASMA | NIR | D | 775-900nm | 9 nm | 0.9 pm | 0.01/cm |
HF-8999-PK-LLL-** | VIS | D | See Brillouin HyperFine | 1.0 pm | 0.04/cm | |
*-UHR | 2X resolution upgrade to any model. |
Notes
- Form Factors;
- A dimensions; 250 x 600 x 150mm, weight; 20kg
- B dimensions; 560 x 330 x 150mm, weight; 23kg
- C dimensions; 160 x 200 x 100mm, weight; 1.5kg
- D dimensions; 700 x 150 x 400mm, weight; 28kg
- E dimensions; 700 x 150 x 250mm, weight 28kg
- *Range and resolution are measured at the middle of the wavelength range
- Accuracy: < 200pm for fixed grating units, <20pm for all others following calibration, an external calibration source is required
- Dynamic Range: 100:1 to 500:1 in a single shot measurement, up to 50dB with exposure bracketing
- Simultaneous range / resolution: >10,000 at 532nm
- Acquisition speed: >10Hz typical
- **HF-8999-532-AUTO is specifically designed for Brillouin scattering and includes a multi-pass etalon for 532nm elastic scattering suppression.
Options
- MMF input with a 10um slit, SMF input with no slit is standard
- Low resolution mode, covers the total range with 0.2nm resolution
- Camera Options;
- CMOS for laser characterization, passive element characterization, Brillouin, Raman and solar spectroscopy
- CCD for low light applications (non -scanning of Brillouin biological samples)
- Scientific CMOS for low light applications requiring fast acquisition
- ICCD for applications requiring gating (LIBS)
- UV C-MOS with good quantum efficiency down to 260nm
HyperFine HN Series for Bright Sources
Kompaktowe spektrometry o rozdzielczości pikometrycznej do mocnych źródeł (~lasery).
The HN series of spectrometers are designed for characterizing high intensity sources such as laser spectra, the HN Series spectrometers from LightMachinery are capable of 1 picometer resolution. These spectrometers achieve the resolution of large gratings spectrometers while covering a larger wavelength range. Simple PC based software allows the user to review spectra in real time and save or export for more analysis. Labview drivers enable the Hornet spectrometer to be integrated into automated experimental setups.
Check out the latest research papers that have been published by researchers using the HyperFine spectrometers here.
Specifications
- Resolution: sub 20pm at 532nm (resolving power > 25,000)
- Accuracy: < 200pm for fixed grating units, <20pm for all others following calibration, an external calibration source is required
- Dynamic Range: 100:1 to 500:1 in a single shot measurement, up to 50dB with exposure bracketing
- Wavelength range: Visible to near IR (260nm to 1080nm*)
- Simultaneous range / resolution: >10,000 at 532nm
- Acquisition and processing speed: >10 Hz
Features
- Simple to use
- Sub 30pm picometer resolution
- Fiber optic input
- Quick data acquisition and export
- Simple USB interface
- LabView Drivers
- No moving parts (single shot laser spectrum analysis)
Benefits
- Range - resolution ratio up to 10,000
- Fast
- Ultra-Compact
- Can measure spectra from cw and pulsed sources
- Fast real time measurements
- Ultra-reliable
- LightMachinery's legendary customer support
Applications
The Hornet spectrometer is ideal for;
- Light source characterization
- Lasers
- Diode Lasers
- Super luminescent diodes
- Monitoring laser modes in real time
- Passive components (Filters, Etalons, Fiber Braggg gratings) characterization to the 25pm level
- Checking the spectral / mode purity of lasers
- Classic undergraduate and graduate experiments
Software
- Our new SpectraLoK software is designed to be a reliable, feature packed interface for setting up your LightMachinery spectrometer, viewing spectra and organizing your data. You can download and try it (it is a .exe file so your anti-virus software might require some reassurance)
Specifications
Part Number | Spectral Region | Form Factor | Total range | Simultaneous range | Resolution* | Resolution |
with manual grating rotation | without grating rotation | pm | 1/cm | |||
HN-8888-UV | UV | C | 200 - 400nm | fixed 60nm range | <30pm | 0.9/cm |
HN-9332 | VIS | E | fixed grating | 425 - 700 nm | <30pm | 0.9/cm |
HN-8989-1 | VIS | B | 400 - 500 nm | 15 nm | 1.7 pm | 0.08/cm |
HN-8989-2 | VIS | C | 500 - 600 nm | 15 nm | 1.6 pm | 0.05/cm |
HN-8989-3 | VIS | B | 600 - 700 nm | 15 nm | 1.9 pm | 0.04/cm |
HN-9353 | NIR | A | 700 - 1050 nm | 350 nm | <40 pm | 0.50/cm |
HN-8995-1 | NIR | C | 700 - 800 nm | 25 nm | 2.0 pm | 0.03/cm |
HN-8991-3 | NIR | B | 800-950 nm | 20 nm | 2.0 pm | 0.02/cm |
HN-8995-2 | NIR | B | 950 - 1100 nm | 20 nm | 2.5 pm | 0.02/cm |
HN-9354 | 1um Lasers | A | 1010nm - 1080nm | fixed grating | 15pm | 0.1/cm |
HN-9352 | Visible & IR | A | YAG, (532 ±2nm and 1064 ±4nm) | fixed grating | 15pm | 0.1/cm |
*-UHR | 2X resolution upgrade to any model. |
Notes
- Form Factors;
- A dimensions; 200 x 200 x 90mm, weight; 2.0 Kg
- B dimensions; 250 x 600 x 150mm, weight; 20Kg
- C dimensions; 560 x 330 x 150mm, weight; 23Kg
- D dimensions; 200 x 200 x 125mm, weight; 2.5Kg
- E dimensions; 125 x 150 x 50mm, weight; 1.5Kg
- F dimensions; 700 x 150 x 400mm, weight; 28Kg
- *Range and resolution are measured at the middle of the wavelength range
- Accuracy: < 200pm for fixed grating units, <20pm for all others following calibration, an external calibration source is required
- Dynamic Range: 100:1 to 500:1 in a single shot measurement, up to 50dB with exposure bracketing
- Simultaneous range / resolution: >10,000 at 532nm
- Acquisition speed: >10Hz typical
Brillouin HyperFine Spectrometer
Make Fast Brillouin Shift Measurements with the HF-8999-PK-LLL.
LightMachinery’s proprietary fluid jet polishing process is utilized to create both the tunable etalon filter and the main VIPA etalon in the spectrometer. The result of the combination of the high finesse elements is unparalleled sensitivity and relatively compact size, perfect for Brillouin scattering. Brillouin measurements are now possible with a greater than 50X speed improvement over current technologies. Welcome to a new world of Brillouin measurements, where data can be collected quickly and easily.
The high optical throughput enables the Brillouin HyperFine Spectrometer, HF-8999, to make rapid measurements of the Brillouin shift that have not previously been possible. Changes in the state of samples can be observed in real-time. To demonstrate, take a look at this quick video showing the Brillouin shift of Loctite 495 instant glue as it sets. Note the fast shift at the 100-second mark.
Check out the latest research papers that have been published by researchers using the HyperFine spectrometers here.
Complete Brillouin Systems (laser, confocal setup and microscope)
In addition to the spectrometer, LightMachinery has developed a complete Brillouin system that includes a high power laser, the VIPA based Brillouin HyperFine spectrometer, a confocal beam sending the laser to the microscope and returning the return signal to the spectrometer, a Nikon microscope with motorized X,Y scanning system to produce fast complete 2D Brillouin Maps, all required software, computer hardware, keyboard an monitor. Everything that is required to create Brillouin Shift Maps of your samples. Contact us for more details.
Technical specification
Wavelength ranges
Part Number | HF-8999-532-AUTO | HF-8999-660-AUTO | HF-8999-780-AUTO |
Wavelength range | 531nm to 534nm | 658nm to 662nm | 780 +/- 2nm |
Spectral resolution | 1pm |
Dynamic range ,at 6GHz from pump (Contrast) | >100dB |
Pump wavelength filter suppression | >30dB |
Pump suppression filter tunability | +/- 1nm |
Pump suppression filter width | 0.5pm |
Fiber input | SMF only |
USB 3.1 | >1A required |
Dimensions | 71 x 37 x 15 cm |
Weight | 25kg |
Features
- Computer controlled alignment and adjustment
- High throughput enabling fast acquisition
- 80dB contrast and high pump suppression
- High resolution and high precision
- Easy to Use
- Large spectral range covered in a single shot
- Simple integration - compact size
- An affordable device that is ready to use out of the box
Software
Our new SpectraLoK software is designed to be a reliable, feature packed interface for setting up your LightMachinery spectrometer, viewing spectra and organizing your data. You can download and try it (it is a .exe file so your anti-virus software might require some reassurance). Click here to download the SpectraLoK Software , this includes a short cut to the experimental virtual camera to allow the partial use of the software without a spectrometer.
Ultrabright Spectrometer
Your spectrometer would work great if you had 100X the light. Problem solved. Introducing the UltraBright Spectrometers from LightMachinery. No slit, just a giant aperture and a huge field of view.
These spectrometers are ideal when;
- Remote sensing or looking at an extended or distant source (something large not a <1mm spot).
- Observing a few bright lines (not a broadband source)
- The application requires high resolution
Now you can collect a lot of light and not worry about trying to convince it to pass through a tiny slit. We have listed here a few of the wavelength range and resolution models but many variations with more or less range and resolution are simple for us to make so let us know what you need, we are happy to help.
Check out the latest research papers that have been published by researchers using the HyperFine spectrometers here.
Think the UltraBright might be the right choice for your application? Contact LightMachinery to become a Beta User of our new UltraBright Spectrometer.
Preliminary Specifications
- Acquisition and processing speed: >5 Hz
- Greater than 1 degree field of view is typical
Part Number | Spectral Region | Wavelength Range | Resolution |
UB-50 | Visible / NIR | Any 50nm window between 450 to 1000nm (for example 550nm to 600nm) | 50pm* |
UB-10 | Visible | Any 10nm window between 450 to 1000nm (for example 600nm to 610nm) | 10pm** |
UB-XX | UV-Visible-IR | Custom - let us know what you need | XXpm |
Software
Our new SpectraLoK software is designed to be a reliable, feature packed interface for setting up your LightMachinery spectrometer, viewing spectra and organizing your data. You can download and try it (it is a .exe file so your anti-virus software might require some reassurance)
Click here to download the SpectraLoK Software , this includes a short cut to the experimental virtual camera to allow the partial use of the software without a spectrom
Ultra OSA
Custom HyperFine
Sometimes you need something special
Michelsons, VIPAs, etalons, gratings, polarizing, non-polarizing, field widened, single mode, cemented, optically contacted (epoxy free bonded), hexagonal, square, small (1mm), large (45mm), UV, visible, IR. Material selection, camera selection, software, coating design, modeling of phase & polarization, mechanical design, process development, quality planning, glass shaping and polishing, optical contacting, cementing and finally testing, testing and testing. We have made a lot variants but the possibilities and unique requirements are endless, of course that's what makes it so interesting and challenging to work on these projects.
If you have a need for a custom spectrometer do not hesitate to contact us to discuss the various parameters and trade-offs. Free advice is our specialty.