SYSTEMY RAMANA

Do pomiarów ramanowskich proponujemy 2 typy spektrometrów: Maya2000 Pro i QE Pro, które konfigurujemy zależnie od zastosowania.

 

 

 

 

 

Example Configurations and Predicted Performance, to complete your modular Raman system, add a 785 nm Raman excitation laser, sample holder, and software

QE Pro with Raman Laser Excitation Grating Slit Raman Shift Resolution
532 nm 1200 lines/mm 10 µm 150-4000 cm-1 ~8 cm-1
532 nm 1200 lines/mm 25 µm 150-4000 cm-1 ~10 cm-1
532 nm 600 lines/mm 10 µm 150-7500 cm-1 ~16 cm-1
532 nm 600 lines/mm 25 µm 150-7500 cm-1 ~19 cm-1
785 nm 1200 lines/mm 50 µm 150-2100 cm-1 ~6 cm-1
785 nm 1200 lines/mm 100 µm 150-2100 cm-1 ~8 cm-1
785 nm 600 lines/mm 50 µm 150-3950 cm-1 ~13 cm-1
785 nm 600 lines/mm 100 µm 150-3950 cm-1 ~18 cm-1
 
  • Portable – small footprint, light weight, fiber optic-based spectrometer
  • Sensitive – high quantum efficiency detector
  • Powerful – signal-to-noise ratio of >1000:1
  • Stable – cooled detector allows low light detection and prevents spectral distortion

 

 

QE Pro-Raman is a preconfigured for 785 nm Raman excitation, using a 900 lines/mm grating H36 grating and 50 µm slit and includes Ocean View software.

Engineering Specifications QE Pro-Raman
PHYSICAL  
Dimensions: (L x W x H) mm and inches 182 mm (7.17 in.) x 110 mm (4.33 in.) x 47 mm (1.85 in.)
Weight: kg and lb Spectrometer: 1.15 kg (2.6 lbs.); power supply: 0.45 kg (1 lb.)
DETECTOR  
Type: Hamamatsu scientific grade, back-thinned, TE Cooled, 1044 x 64 element CCD array
Range: 185-1100 nm
Quantum efficiency: 90% (peak)
SPECTROSCOPIC  
Wavelength range: 780-1000 nm
Raman shift: 0-2800 cm-1
Resolution: 7 – 11 cm-1 over the range*
Integration time: 8 ms to 60 minutes
Dynamic range: ~85,000:1
Signal-to-noise ratio: System: 1000:1 (single acquisition)
Stray light: <0.08% at 600 nm; 0.4% at 435 nm
Buffering: 15,000 spectra
Fiber optic connector: SMA 905 and Ocean Optics FC
ELECTRONICS  
Power requirement: Supply voltage: 4.5 – 5.5 V
Strobe functions: continuous and single strobe
Interfaces: USB 2.0, 480 Mbps (USB 1.1 compatible); RS-232 (5-wire)
OPERATING CONDITIONS  
Operating temperature: 0 °C – 50 °C
Humidity: ≤ 90% noncondensing

* Resolution in wavenumbers varies with the wavelength being measured. It is higher close to the laser, and lower at longer Raman shifts.

 

 

 

Maya2000 Pro-NIR is an application-ready, high-sensitivity spectrometer ideal for Raman and low light level shortwave NIR applications. The Maya2000 Pro-NIR is optimized for the 780-1180 nm region and includes a 760 nm longpass filter, 50 µm slit and gold mirrors for enhanced NIR reflectivity. 

 
  • Compact – small footprint
  • Powerful – high performance optical bench and low-noise electronics
  • Plug-and-play – easy connectivity and adaptability with other devices

 

PHYSICAL Maya2000 Pro-NIR
Dimensions: 148.6 x 109.2 x 46.4 mm without feet

148.6 x 109.2 x 49.3 mm with feet

Weight: 0.96 kg (2.1 lb.)
DETECTOR

 

Type: Back-thinned, 2D
Detector: Hamamatsu S11510 (uncooled)
Quantum efficiency: ~85% peak QE @ 700 nm; 40% QE @ 1000 nm
SPECTROSCOPIC  
Spectral range (preset): 780-1180 nm
Optical resolution (FWHM): ~0.82 nm
Signal-to-noise ratio at full signal: ~450:1
Grating: Grating #H14
Dynamic range: 15000:1 (typical)
Integration time: 7.2 ms-5 seconds
Fiber optic connector: SMA 905 to 0.22 numerical aperture single-strand optical fiber
ELECTRONICS  
Power requirement: 500 mA @ 5 VDC
Trigger modes: 4 modes
Strobe functions: Yes
Interfaces: USB 2.0, RS-232
ENVIRONMENTAL and COMPLIANCE  
Temperature: 0 °C to 50 °C (operation)
Humidity: 0-90% non-condensing
Material: RoHS
Electrical: EN61326-1:2013, CISPR 11:2009/A1:2010

 